DoorKing 1812 Classic El manual del propietario

Busca en linea o descarga El manual del propietario para Sistemas de intercomunicación de la puerta DoorKing 1812 Classic. DoorKing 1812 Classic Owner`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 2
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
CENTRAL
OFFICE
EARTH
GND
PHONE
IN
PHONE
OUT
HOME
2345678
SW1
ENTRY BY-PASS
1875-010
1
CENTRAL
OFFICE
EARTH
GND
PHONE
IN
PHONE
OUT
HOME
2345678
SW1
ENTRY BY-PASS
1875-010
It is highly recommended that you consult the Installation/Owner’s manual for complete instructions on all the different types of installations. The 1812 Classic Telephone
Entry System involves the installation of the 1812 Classic cabinet, the by-pass board for the incoming telephone line, and wiring of these components (On reverse side). Be
sure that all dirt, metal or wood debris is removed from inside cabinet after mounting it. This could damage the control board and cause a malfunction during operation.
Remove Control Board from Cabinet
Flush Mount Cabinet in a Pilaster, Wall or Kiosk
The control board removal is the same for all models.
1. Unlock and open the 1812 Classic door.
2. Disconnect the keypad plug and door accessories
plug from the control board.
3. Remove the 4 screws. Carefully remove control board.
CAUTION Keep the control board in a protected area
during the installation.
Use existing 4 holes in cabinet box to bolt the surface or wall mount models on a DoorKing
mounting post (there are several different styles available). Use the hardware that is supplied with
the mounting post. Run all necessary wires through the post to the cabinet (See reverse side).
Mount Cabinet on a Mounting Post
Use the 4 existing holes in the cabinet box to screw the surface or wall mount models to
the wall. Run conduit inside or outside of wall or pilaster if desired. Use appropriate
hardware to mount the cabinet (Not supplied). Be sure that the mounting hardware does
not protrude into the cabinet where it could cause a short. Run all necessary wires through
the conduit to the cabinet (See reverse side).
Mount Cabinet Directly to a Wall or Pilaster
Install the By-Pass Board
The 1812 Classic by-pass board provides a method to by-pass the 1812 Classic and route the incoming
telephone line directly to the homeowner’s phone. It must be installed as part of the 1812 Plus system.
All telephone wires for the 1812 Classic must pass through the by-pass board.
Mount the by-pass board in a location that is easily accessible by the homeowner. In case of 1812 trouble
or maintenance, the homeowner will use the by-pass switch on the board to route the incoming telephone
line directly to their home phone. If the by-pass board is installed outdoors, it must be installed in a NEMA
Type 4 enclosure (not supplied) with conduit to protect the board and wires from direct exposure to
landscape sprinklers, rain, snow, and other elements.
NEMA Type 4
enclosure for
outdoor
installation.
(Not Supplied)
Use only twisted pair telephone wire that is rated for direct
underground burial (Cat5e Gel Filled (flooded) UV resistant
direct burial cable in conduit is recommended).
DO NOT use wire that is rated for indoor application use.
DO NOT run telephone wires in the same conduit as high
voltage AC wire.
It is recommended to run all necessary wires to the by-pass
board (See reverse side) in a “dedicated” telephone wire
conduit.
Ground by-pass board.
Minimum 12 AWG wire
(Not supplied).
If installed
outdoors.
Plastic screw anchors for
masonry if required.
(Not supplied)
Dedicated
Telephone
Wire Conduit
“Entry” switch position:
Routes incoming phone line through 1812 Classic
and then to the home phone.
“By-Pass” switch position:
Routes incoming phone line directly to the
home phone, bypassing 1812 Classic.
From
Incoming
Telephone
Line
From
1812 Plus
18-Pin
Main
Terminal
Surface
Mount
Cabinet
Wall
Mount
Cabinet
Flush
Mount
Cabinet
7
7
8 9
4 5 6
1 2 3
0
7
8
9
4
5 6
1 2 3
0
7
8 9
4
5 6
1
2 3
0
Mount rough-in box into the pilaster, wall or kiosk. Run conduit inside wall into bottom of rough-in
box if desired. Use appropriate hardware (Not supplied) to secure the rough-in box in place. Run all
necessary wires through the conduit in to the rough-in box (See reverse side).
Bolt flush mount box
into the rough-in box
with 4 supplied bolts.
R
ough-In Box
Flush
Mount
Box
7
8
9
4 5
6
0
Conduit
(Shown inside wall)
Conduit
(Shown inside wa
ll)
IMPORTANT The 1812 Classic and
by-pass board MUST be properly
grounded! A gooseneck mounting
post anchored in concrete does not
make a good ground.
1
CENTRAL
O
FFICE
EARTH
G
ND
PHONE
IN
PHONE
OUT
HOME
2345
6
7
8
SW1
ENTRY BY-PASS
1875-010
2
3
4
5
6
7
8
1
From
Home
Phone
Incoming
Phone Line
Home Phone
Incoming
Phone Line
Home Phone
7 8 9
4 5 6
1 2 3
0
1
1
1
1
2
2
2
2
3
3
3
3
7 8 9
4 5 6
0
Remove the 18-pin main terminal
connector from the control board by
gently pulling it straight up. This will
make wiring to the control board
easier. Note the orientation and
numbering sequence of the
connector to correctly wire it.
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
QUICKSTART “BASIC” INSTALLATION GUIDELINES FOR AN 1812 CLASSIC CABINET AND BY-PASS BOARD
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - Install the By-Pass Board

120 Glasgow AvenueInglewood, California 90301U.S.A.1817161514131211109876543211CENTRALOFFICEEARTHGNDPHONEINPHONEOUTHOME2345678SW1ENTRY BY-PASS1875-010

Pagina 2 - Control Board

MICVOLFB1FB2MASTERCODEON1871-010120 Glasgow AvenueInglewood, California 90301U.S.A.EARTHGNDSW1ENTRY BY-PASS1875-0101CENTRALOFFICEPHONEINPHONEOUTHOME23

Comentarios a estos manuales